Promise Technology FastTrak SX4000 Lite User Manual Page 27

  • Download
  • Add to my manuals
  • Print
  • Page
    / 78
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 26
Chapter 3: FastBuild™ Utility
21
Gigabyte Boundary
The Gigabyte Boundary feature is designed for fault tolerant arrays (RAID 1, 0+1
and 5) in which a drive has failed and the user cannot replace the drive with the
same capacity or larger. Instead, the Gigabyte Boundary feature permits the
installation of a replacement drive that is slightly smaller (within 1 gigabyte) than
the remaining working drive (for example, an 80.5 GB drive would be rounded
down to 80 GB). This can be helpful in the event that a drive fails and an exact
replacement model is no longer available.
For the Gigabyte Boundary feature to work, the Gigabyte Boundary feature must
be set to ON when the original array is created. When enabled, the Gigabyte
Boundary feature rounds the drive capacity of all drives to the common whole GB
drive size. For example, with the Gigabyte Boundary feature enabled, the
remaining working drives can be 80.5 GB and the replacement drive can be 80.3,
since all are rounded down to 80GB. This permits the smaller drive to be used.
Please note that users will lose a small amount of available storage capacity from
each drive in order to arrive at a common drive size.