FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual
16
Status
Shows one of three possible array status conditions:
Functional
The array is fully operational, and no problems are present.
Critical
The array is operational, but has lost its fault tolerance. For RAID array
levels 1, 0+1 and 5 the array contains a failed drive. The user should
identify and replace the failed drive.
Offline
The array is no longer operational and the FastBuild utility cannot rebuild
the array. The array must be rebuilt from the last tape backup or other
device. The user should identify and replace the failed drives. For RAID
levels 1 and 5, at least two or more drives in the array have failed. For a
RAID 0 or JBOD array, at least one drive has failed.