190
System was shut down
abnormally.
The SmartStor shut down incorrectly the last time.
See “Shutting Down the SmartStor” on page 167.
CPU temperature is
higher than 58°C/138°F.
System will shut down.
Allow the SmartStor to cool for several minutes. Then
restart the SmartStor and check system temperature
and fan operation. See page 169.
Be sure there is adequate air circulation around the
SmartStor.
System fan speed is lower
than 1800 RPM. Check
the system before
continuing.
Try enabling or disabling the Smart Fan. See
page 169. If the fan still runs below 1800 RPM,
contact Technical Support. See page 205.
AC Power failure. System
will shut down.
Restore the AC power. Then restart the SmartStor.
See “Connecting the Power” on page 8.
Disk Drives
Task X timeout on disk Y
at LBA [address]
A LBA error. Check the disk drives. See page 182.
Check the RAID Volume. See page 184. Replace the
disk drive or rebuild the RAID Volume as needed.
Task X disk error on disk
Y at LBA [address] with
status Z
S.M.A.R.T threshold
exceeded on disk X
Check the disk drives. See page 182. Replace the
failed drive. See page 183.
BSL update on disk X at
LBA [address]
Bad sector on a disk drive. Check the disk drives.
See page 182. Replace the disk drive if it continues to
receive BSL updates.
BSL log disk X at LBA
[address] cleared
Check the disk drives. See page 182.
Delete Spare Disk Delete a spare drive. Normal.
RAID Volumes
Create [RAID name,
RAID level and X number
of disk drives]
Create a RAID Volume. Normal.
Delete RAID X Delete a RAID Volume. Normal.
Migration or Rebuilding
on array X started.
RAID Volume Migration or Rebuild has started.
Normal.
Migration or Rebuilding
on array X at Y%.
Progress report on RAID Volume Migration or
Rebuild. Normal.
Reported Event Corrective Action